652-770
Explanation: A non-critical error has been detected: intermediate system bus address parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C8
v FFC_292
652-771
Explanation: A non-critical error has been detected: intermediate or system bus data parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C8
v FFC_292
652-772
Explanation: A non-critical error has been detected: intermediate or system bus time-out error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2D2
v FFC_292
652-773
Explanation: A non-critical error has been detected: intermediate or system bus data parity error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_227
652-88X
Explanation: The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit error and location codes, for the
necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics in problem determination mode
and record and report the 8-digit error and location codes for this SRN.
Response:
652-770 • 652-88X
Chapter 8. Troubleshooting 315

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals