EasyManuals Logo

IBM Flex System p260 User Manual

IBM Flex System p260
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #328 background imageLoading...
Page #328 background image
652-89X
Explanation: The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit error and location codes, for the
necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics in problem determination mode
and record and report the 8-digit error and location codes for this SRN.
Response:
814-112
Explanation: The NVRAM test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_814
814-113
Explanation: The VPD test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_221
814-114
Explanation: I/O Card NVRAM test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_814
815-100
Explanation: The floating-point processor test failed. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_815
652-89X • 815-100
316 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide