2625-701
Explanation: Error Log Analysis indicates that this adapter has failed due to an internal error. Replace the 2-port
QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625
2625-702
Explanation: Error Log Analysis indicates that this adapter has failed due to a failure with the uplink interface used
to connect this device to the host processor. Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625
2625-703
Explanation: Error Log Analysis indicates that this adapter has failed due to a memory error. Replace the 2-port
QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625
2625-704
Explanation: Error Log Analysis indicates that this adapter has failed due to a unrecoverable internal parity error.
Replace the 2-port QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625
2625-705
Explanation: Error Log Analysis indicates that this adapter has failed due to a internal error. Replace the 2-port
QDR 40 GB/S InfiniBand expansion card (CFFh).
Response:
Failing Item:
v FFC_2625