EasyManua.ls Logo

IBM Flex System p260 - Page 365

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
268B-120
Explanation: A SCSI busy or command error. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-122
Explanation: A SCSI reservation conflict error. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-124
Explanation: A SCSI check condition error occurred. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-126
Explanation: A software error was caused by a hardware failure. Replace the 300 GB SFF SAS Hard Disk Drive. Run
diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v FFC_268B
v FFC_B88
268B-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_268B
268B-120 268B-128
Chapter 8. Troubleshooting 353