268B-129
Explanation: Error log analysis indicates a SCSI bus problem. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_268B
268B-130
Explanation: Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Replace
the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-132
Explanation: A disk drive hardware error occurred. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_268B
268B-134
Explanation: The adapter failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v SOFTWARE
268B-135
Explanation: The device failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_268B
v FFC_B88
v SOFTWARE
268B-129 • 268B-135
354 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide