26D2-129
Explanation: Error log analysis indicates a SCSI bus problem. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D2
26D2-130
Explanation: Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Replace
the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-132
Explanation: A disk drive hardware error occurred. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-134
Explanation: The adapter failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v SOFTWARE
26D2-135
Explanation: The device failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26D2
v FFC_B88
v SOFTWARE
26D2-129 26D2-135