26D2-120
Explanation: A SCSI busy or command error. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-122
Explanation: A SCSI reservation conflict error. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-124
Explanation: A SCSI check condition error occurred. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D2-126
Explanation: A software error was caused by a hardware failure. Replace the 600 GB SFF SAS Hard Disk Drive. Run
diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v FFC_26D2
v FFC_B88
26D2-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D2
26D2-120 • 26D2-128
364 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide