26D2-640
Explanation: Error log analysis indicates a path error. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D2
26D7-102
Explanation: An unrecoverable media error occurred. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-104
Explanation: The motor failed to restart. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-105
Explanation: The drive did not become ready. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-106
Explanation: The electronics card test failed. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-108
Explanation: The bus test failed. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D2-640 • 26D7-108