26D7-110
Explanation: The media format is corrupted. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-112
Explanation: The diagnostic test failed. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-114
Explanation: An unrecoverable hardware error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-116
Explanation: A protocol error.
1. Make sure that the firmware of the FRUs shown and the parent adapter, are compatible with the diagnostic and
application software levels.
2. If you do not find a problem, call your operating-system support person.
Response:
Failing Item:
v FFC_26D7
26D7-117
Explanation: A write-protect error occurred. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-110 26D7-117
368 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide