26D7-118
Explanation: A SCSI command time-out occurred. Replace the 900 GB SFF SAS Hard Disk Drive. Run diagnostics
again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v FFC_26D7
v FFC_B88
26D7-120
Explanation: A SCSI busy or command error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-122
Explanation: A SCSI reservation conflict error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-124
Explanation: A SCSI check condition error occurred. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-126
Explanation: A software error was caused by a hardware failure. Replace the 900 GB SFF SAS Hard Disk Drive. Run
diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v FFC_26D7
v FFC_B88
26D7-118 26D7-126