2E23-604
Explanation: Error log analysis indicates transmission errors.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E23
2E28-201
Explanation: Adapter configuration error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter If
the problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E28
v FFC_221
2E28-601
Explanation: Adapter taken off-line. Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E28
2E28-602
Explanation: Adapter parity error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E28
2E28-603
Explanation: Permanent adapter failure. Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E28
2E23-604 2E28-603
Chapter 8. Troubleshooting 397