2E28-604
Explanation: Adapter down error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E28
2E29-201
Explanation: Adapter configuration error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter If
the problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E29
v FFC_221
2E29-601
Explanation: Adapter taken off-line. Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E29
2E29-602
Explanation: Adapter parity error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E29
2E29-603
Explanation: Permanent adapter failure. Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E29