2D14-4101
Explanation: Temporary device bus fabric error. Use MAP3152 to determine resolution.
Response:
2D14-4110
Explanation: Unsupported enclosure function detected. Use MAP3145 to determine resolution.
Response:
2D14-4150
Explanation: PCI bus error detected by controller. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
2D14-4160
Explanation: PCI bus error detected by controller. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
2D14-7001
Explanation: Temporary disk data error. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_722
2D14-8150
Explanation: Controller failure. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
2D14-4101 • 2D14-8150
422 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide