EasyManua.ls Logo

IBM Flex System p260 - Page 435

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2D14-8157
Explanation: Temporary controller failure. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
2D14-9000
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D14-9001
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D14-9002
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D14-9008
Explanation: Controller does not support function expected for one or more disks. Use MAP3130 to determine
resolution.
Response:
2D14-9010
Explanation: Cache data associated with attached disks cannot be found. Use MAP3120 to determine resolution.
Response:
2D14-9011
Explanation: Cache data belongs to disks other than those attached. Use MAP3190 to determine resolution.
Response:
2D14-9020
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Use MAP3111 to determine
resolution.
Response:
2D14-8157 2D14-9020
Chapter 8. Troubleshooting 423

Table of Contents

Related product manuals