EasyManuals Logo

IBM Flex System p260 User Manual

IBM Flex System p260
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #443 background imageLoading...
Page #443 background image
2D29-4101
Explanation: Temporary device bus fabric error. Use MAP3152 to determine resolution.
Response:
2D29-4110
Explanation: Unsupported enclosure function detected. Use MAP3145 to determine resolution.
Response:
2D29-4150
Explanation: PCI bus error detected by controller. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-4160
Explanation: PCI bus error detected by controller. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-7001
Explanation: Temporary disk data error. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_722
2D29-8150
Explanation: Controller failure. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-4101 • 2D29-8150
Chapter 8. Troubleshooting 431

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish