2D29-8157
Explanation: Temporary controller failure. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-9000
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9001
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9002
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9008
Explanation: Controller does not support function expected for one or more disks. Use MAP3130 to determine
resolution.
Response:
2D29-9010
Explanation: Cache data associated with attached disks cannot be found. Use MAP3120 to determine resolution.
Response:
2D29-9011
Explanation: Cache data belongs to disks other than those attached. Use MAP3190 to determine resolution.
Response:
2D29-9020
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Use MAP3111 to determine
resolution.
Response:
2D29-8157 2D29-9020