EasyManuals Logo

IBM Flex System p260 User Manual

IBM Flex System p260
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #444 background imageLoading...
Page #444 background image
2D29-8157
Explanation: Temporary controller failure. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-9000
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9001
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9002
Explanation: Controller detected device error during configuration discovery. Use MAP3190 to determine resolution.
Response:
2D29-9008
Explanation: Controller does not support function expected for one or more disks. Use MAP3130 to determine
resolution.
Response:
2D29-9010
Explanation: Cache data associated with attached disks cannot be found. Use MAP3120 to determine resolution.
Response:
2D29-9011
Explanation: Cache data belongs to disks other than those attached. Use MAP3190 to determine resolution.
Response:
2D29-9020
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Use MAP3111 to determine
resolution.
Response:
2D29-8157 • 2D29-9020
432 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals