2D29-9074
Explanation: Multiple controllers not capable of similar functions or controlling same set of devices. Use MAP3141
to determine resolution.
Response:
2D29-9075
Explanation: Incomplete multipath connection between controller and remote controller. Use MAP3149 to determine
resolution.
Response:
2D29-9076
Explanation: Missing remote controller. Use MAP3147 to determine resolution.
Response:
2D29-9081
Explanation: Controller detected device error during internal media recovery. Use MAP3190 to determine resolution.
Response:
2D29-9082
Explanation: Controller detected device error during internal media recovery. Use MAP3190 to determine resolution.
Response:
2D29-9090
Explanation: Disk has been modified after last known status. Use MAP3133 to determine resolution.
Response:
2D29-9091
Explanation: Incorrect disk configuration change has been detected. Use MAP3133 to determine resolution.
Response:
2D29-9092
Explanation: Disk requires Format before use. Format the disk and retry the operation. Use MAP3134 to determine
resolution.
Response:
2D29-9074 2D29-9092
436 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide