EasyManua.ls Logo

IBM Flex System p260 - Page 449

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2D29-FF3D
Explanation: Temporary controller failure. Retry the operation. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-FFF3
Explanation: Disk media format bad. Reformat the disk and retry the operation. Use MAP3135 to determine
resolution.
Response:
2D29-FFF4
Explanation: Device problem. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D29-FFF6
Explanation: Device detected recoverable error. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D29-FFFA
Explanation: Temporary device bus error. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D29-FFFE
Explanation: Temporary device bus error. Use MAP3150 to determine resolution.
Response:
2D29-FF3D 2D29-FFFE
Chapter 8. Troubleshooting 437

Table of Contents

Related product manuals