EasyManuals Logo

IBM Flex System p260 User Manual

IBM Flex System p260
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #477 background imageLoading...
Page #477 background image
Table 20. Hypervisor isolation procedures and symbolic failing items (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom Action
MASBUS The multi-adapter
bridge detected a
problem with a
connection to a PCI
adapter that it
controls.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
MEMDIMM The failing
component is one of
the memory DIMMs.
1. Replace the failing DIMM. See “Removing a DIMM” on page 55 for
location information and for the removal procedure.
2. Install new memory DIMMs, as described in “Installing a DIMM” on
page 58.
For more information, see “Supported DIMMs” on page 59.
NEXTLVL Contact IBM Support.
OPT_CLN This item does not apply to compute nodes. Continue with the next item in the failing item list.
PCIE_SW The PCIe switch
might be the failing
item.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
PCIEBUS The PCIe bus might
be the failing item.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
PIOCARD The hardware that
controls PCI adapters
and PCI card slots
detected an error. The
direct select address
(DSA) portion of the
system reference code
(SRC) identifies the
location code of the
failing component.
Use the “PCI expansion card (PIOCARD) problem isolation procedure”
on page 462 to determine the failing component.
PRI_PCI This item does not apply to compute nodes. Continue with the next item in the failing item list.
PSI_LNK The path to the
service processor
might be the failing
item.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
SICNTRL This item does not apply to compute nodes. Continue with the next item in the failing item list.
SIIOADP The I/O hub or I/O
bridge might be
failing.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
Chapter 8. Troubleshooting 465

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals