MAP 0900: Parallel Port
Symptom Explanation
Conditions That Could Cause This
Symptom
You have entered this
MAP because you
received a 9XX error
code, you suspect a par-
allel port problem, or you
have been directed here
from another MAP.
The system board is failing.
The communications cable is failing.
The setup is incorrect.
001
– Power off the system unit.
– Remove all adapter cards from the riser card.
– Insert the Advanced Diagnostics diskette into drive A.
– While holding down both mouse buttons, power on the system unit. This
automatically sets the parallel port configuration correctly.
– Run the Parallel Port tests. Use the RUN TESTS ONE TIME option.
– Follow the instructions on the screen.
Note: When instructed to install the wrap plug, use IBM P/N 72X8546.
DID YOU RECEIVE AN ERROR MESSAGE?
Yes No
002
You have successfully completed the Advanced Diagnostics tests. If
you suspect an intermittent problem, start an error log. If you need
instructions, refer to “Error Log” on page 3-9.
003
Replace the system board.
2-72