v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, ā€œParts listing, System x3200 Types 4362 and 4363,ā€ on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by ā€œ(Trained service technician only),ā€ that step must be performed only by a
trained service technician.
Symptom Action
The CD or DVD drive tray is not
working.
1. Make sure that the server is turned on.
2. Insert the end of a straightened paper clip into the manual tray-release
opening.
3. Reseat the CD or DVD drive cable.
4. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. CD or DVD drive cable
b. CD or DVD drive
Diskette drive problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, ā€œParts listing, System x3200 Types 4362 and 4363,ā€ on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by ā€œ(Trained service technician only),ā€ that step must be performed only by a
trained service technician.
Symptom Action
The diskette drive activity LED
stays lit, or the server bypasses
the diskette drive.
1. If there is a diskette in the drive, make sure that:
v The diskette drive cables are correctly and securely connected.
v The diskette drive is enabled in the Configuration/Setup Utility program.
v The diskette is good and not damaged. (Try another diskette if you have
one.)
v The diskette is inserted correctly in the drive.
v The diskette contains the necessary files to start the server.
v Your software program is working properly.
2.
To prevent diskette drive read/write errors, make sure that the distance
between monitors and diskette drives is at least 76 mm (3 in.).
3. Replace the diskette drive.
30 System x3200 Types 4362 and 4363: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3200 and is the answer not in the manual?

IBM System x3200 Specifications

General IconGeneral
Form FactorTower
NetworkIntegrated Gigabit Ethernet
ProcessorIntel Xeon 3000 sequence, Intel Pentium Dual-Core processor, Intel Celeron processor
Processor CoresDual-Core
ChipsetIntel 3000
MemoryUp to 8GB DDR2
Memory Slots4
StorageSATA HDD
RAID SupportRAID 0, 1