v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 Types 4362 and 4363,” on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The monitor works when you
turn on the server, but the
screen goes blank when you
start some application
programs.
1. Make sure that:
v The application program is not setting a display mode that is higher than the
capability of the monitor.
v You installed the necessary device drivers for the application.
2.
Run video diagnostics (see “Running the diagnostic programs” on page 43).
v If the server passes the video diagnostics, the video is good; see “Solving
undetermined problems” on page 64.
v (Trained service technician only) If the server fails the video diagnostics,
replace the system board.
The monitor has screen jitter, or
the screen image is wavy,
unreadable, rolling, or distorted.
1. If the monitor self-tests show that the monitor is working correctly, consider the
location of the monitor. Magnetic fields around other devices (such as
transformers, appliances, fluorescent lights, and other monitors) can cause
screen jitter or wavy, unreadable, rolling, or distorted screen images. If this
happens, turn off the monitor.
Attention: Moving a color monitor while it is turned on might cause screen
discoloration.
Move the device and the monitor at least 305 mm (12 in.) apart, and turn on
the monitor.
Notes:
a. To prevent diskette drive read/write errors, make sure that the distance
between the monitor and any external diskette drive is at least 76 mm (3
in.).
b. Non-IBM monitor cables might cause unpredictable problems.
2.
Reseat the monitor cable.
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Monitor
b. (Trained service technician only) System board
Wrong characters appear on the
screen.
1. Reseat the monitor cable.
2. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Monitor
b. (Trained service technician only) System board
36 System x3200 Types 4362 and 4363: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3200 and is the answer not in the manual?

IBM System x3200 Specifications

General IconGeneral
Form FactorTower
NetworkIntegrated Gigabit Ethernet
ProcessorIntel Xeon 3000 sequence, Intel Pentium Dual-Core processor, Intel Celeron processor
Processor CoresDual-Core
ChipsetIntel 3000
MemoryUp to 8GB DDR2
Memory Slots4
StorageSATA HDD
RAID SupportRAID 0, 1
Drive Bays4 internal 3.5-inch

Related product manuals