A single problem might cause more than one error message. When this occurs,
correct the cause of the first error message. The other error messages usually will
not occur the next time POST runs.
Exception: If there are multiple error codes or diagnostics LEDs that indicate a
microprocessor error, the error might be in the microprocessor or in the
microprocessor socket. See “Microprocessor problems” on page 28 for information
about diagnosing microprocessor problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 4364 or Type 4365 server,” on page 59 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
1-1-3 CMOS write/read test failed.
1. Reseat the battery.
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Battery
b. (Trained service technician only)
System board
1-1-4 BIOS EEPROM checksum failed. (Trained service technician only) Replace the
system board.
1-2-1 Programmable interval timer failed. (Trained service technician only) Replace the
system board.
1-2-2 DMA initialization failed. (Trained service technician only) Replace the
system board.
1-2-3 DMA page register write/read failed. (Trained service technician only) Replace the
system board.
1-2-4 RAM refresh verification failed.
1. Reseat the DIMMs.
2. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
1-3-1 First 64K RAM test failed.
1. Reseat the DIMMs.
2. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
2-1-1 Secondary DMA register failed. (Trained service technician only) Replace the
system board.
2-1-2 Primary DMA register failed. (Trained service technician only) Replace the
system board.
2-1-3 Primary interrupt mask register failed. (Trained service technician only) Replace the
system board.
12 IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3250 and is the answer not in the manual?

IBM System x3250 Specifications

General IconGeneral
Processor Sockets1
Memory Slots4
ProcessorIntel Core 2 Duo
StorageSATA
Maximum Internal StorageUp to 4TB
Hard Drive InterfaceSATA
RAID SupportRAID 0, 1
NetworkGigabit Ethernet
Operating System SupportWindows Server, Linux

Related product manuals