Error code Description Action
035-275-001 Adapter Communication error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-276-001 Adapter CPU test error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-277-001 Adapter Local RAM test error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-278-001 Adapter NVSRAM test error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-279-001 Adapter Cache test error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-280-001 Adapter Drive test error. Replace the attached drive.
035-281-001 Adapter Drive error. Replace the attached drive.
035-282-001 Adapter Parameters set error.
1. Update the RAID controller firmware on the RAID
adapter (see “Updating the firmware” on page
107).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
035-283-001 Adapter Battery error. Replace the battery module on the RAID adapter.
035-xxx-cnn c = ServeRAID channel number, nn = ID of
failing fixed disk drive.
1. Check the system-error logs and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the hard disk drive on channel C, ID nn.
3. Replace the hard disk drive on channel C, ID nn.
42 IBM System x3250 Types 4364 and 4365: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3250 and is the answer not in the manual?

IBM System x3250 Specifications

General IconGeneral
Processor Sockets1
Memory Slots4
ProcessorIntel Core 2 Duo
StorageSATA
Maximum Internal StorageUp to 4TB
Hard Drive InterfaceSATA
RAID SupportRAID 0, 1
NetworkGigabit Ethernet
Operating System SupportWindows Server, Linux

Related product manuals