v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 29 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
3-3-3 No operational memory in system.
1. Make sure that the server contains the
correct number of DIMMs, in the correct
order; install or reseat DIMMS; then,
restart the server.
Important: In some memory
configurations, the 3-3-3 beep code might
sound during POST, followed by a blank
monitor screen. If this occurs and the Boot
Fail Count option in the Start Options of
the Configuration/Setup Utility program is
enabled, you must restart the server three
times to reset the configuration settings to
the default configuration (the memory
connector or bank of connectors enabled).
2. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only)
System board
Three short beeps Possible memory error
1. Reseat the DIMMs.
2. Locate the failing DIMMs:
a. Remove all the DIMMs from the server.
b. Beginning with the primary bank of
DIMM connectors, install one bank of
DIMMs at a time in the server,
restarting the server each time untill
the beep code error returns.
c. Rplace one pair of DIMMs at a time in
the failing bank with an identical pair of
known good DIMMs, restarting the
server after each pair, until the beep
code error returns.
d. Replace one DIMM at a time in the
failing pair with an identical known
good DIMM, restarting the server after
each DIMM, to identify the failed
DIMM. If the beep code error remains
after replacing both DIMMs, go to step
3b.
e. Repeat steps 2b through 2d until all
memory banks have been checked.
3. Replace the following components, one at
a time, in the order shown:
a. DIMMs
b. (Trained service technician only)
System board
Chapter 5. Diagnostics 105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 and is the answer not in the manual?

IBM x3550 Specifications

General IconGeneral
Processor TypeIntel Xeon
ChipsetIntel 5000P
Number of Processors Supported2
Network InterfaceDual Gigabit Ethernet
Hard Drive InterfaceSAS/SATA
Maximum Internal Storage2.4 TB
StorageUp to six 2.5-inch SAS or SATA hot-swap hard disk drives
Drive Bays6
RAID SupportRAID 0, 1
Power Supply670W or 835W
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESX
MemoryPC2-5300 Fully Buffered DIMMs (DDR2-667) or PC2-4200 Fully Buffered DIMMs (DDR2-533)

Related product manuals