IDEATEC POLARIS - Electric Wire Dimensioning

IDEATEC POLARIS
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User Guide POLARIS V1.0 - Console V1.16 - Module V2.16
Page 3
0.34
22
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
0.5
20
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
0.75
18
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
1.5
16
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
2.5
14
1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
0.9m
3 Feet
0.9m
3 Feet
X
X
X
X
X
X X X
4
12
1.8m
6 Feet
1.7m
5.5 Feet
1.5m
5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
1.2m
4 Feet
1.2m
4 Feet
1m
3.5 Feet
1m
3.5 Feet
6
10
3.0m
10 Feet
2.7m
9 Feet
2.4m
8 Feet
2.2m
7.5 Feet
2.1m
7 Feet
2m
6.5 Feet
1.8m
6 Feet
1.8m
6 Feet
1.6m
5.5 Feet
10
8
4.7m
15.5 Feet
4.2m
14 Feet
4m
13 Feet
3.6m
12 Feet
3.3m
11 Feet
3.2m
10.5 Feet
3m
10 Feet
2.7m
9 Feet
2.5m
8.5 Feet
16
6
7.6m
25 Feet
6.8m
22.5 Feet
6.2m
20.5 Feet
5.8m
19 Feet
5.3m
17.5 Feet
5m
16.5 Feet
4.7m
15.5 Feet
4.4m
14.5 Feet
4.2m
14 Feet
25
4
12m
39.5 Feet
11m
36 Feet
10m
33 Feet
9.2m
30.5 Feet
8.5m
28 Feet
8m
26.5 Feet
7.4m
24.5 Feet
7m
23 Feet
6.7m
22 Feet
35
2
19.2m
63 Feet
17.3m
57 Feet
16m
52.5 Feet
14.7m
48.5 Feet
13.7m
45 Feet
12.8m
42 Feet
11.8m
39 Feet
11.2m
37 Feet
10.6m
35 Feet
50A 55A 60A 65A 70A 75A 80A 85A 90A
0.34
22
1.8m
6 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X
X
X X X
0.5
20
2.9m
9.5 Feet
1.5m
5 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X X X
0.75
18
4.5m
15 Feet
2.2m
7.5 Feet
1.5m
5 Feet
1.2m
4 Feet
0.9m
3 Feet
X
X
X
X
X
X X X
1.5
16
7.5m
24.5 Feet
3.5m
12 Feet
2.4m
8 Feet
1.8m
6 Feet
1.5m
5 Feet
1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
X X
2.5
14
12m
39 Feet
6m
19.5 Feet
4m
13 Feet
2.8m
9.5 Feet
2.5m
8 Feet
2m
6.5 Feet
1.6m
5.5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
4
12
20m
62 Feet
9.5m
31 Feet
6m
20.5 Feet
4.7m
15.5 Feet
3.8m
12.5 Feet
3.2m
10.5 Feet
2.7m
9 Feet
2.3m
7.5 Feet
2.1m
7 Feet
6
10
30m
98 Feet
15m
49 Feet
10m
32.5 Feet
7.5m
24.5 Feet
6m
19.5 Feet
5m
16.5 Feet
4.2m
14 Feet
3.8m
12.5 Feet
3.3m
11 Feet
10
8
48m
156 Feet
24m
78 Feet
16m
52 Feet
11.8m
39 Feet
9.4m
31 Feet
8m
26 Feet
6.8m
22.5 Feet
5.9m
19.5 Feet
5.3m
17.5 Feet
16
6
75m
248 Feet
37m
124 Feet
25m
82.5 Feet
18.8m
62 Feet
15m
49.5 Feet
12.6m
41.5 Feet
10m
35.5 Feet
9.4m
31 Feet
8.3m
27.5 Feet
25
4
120m
395 Feet
60m
197 Feet
40m
131 Feet
30m
98.5 Feet
24m
79 Feet
20m
66 Feet
17m
56.5 Feet
15m
49.5 Feet
13.4m
44 Feet
35
2
190m
629 Feet
95m
314 Feet
63m
209 Feet
47m
157 Feet
38m
125 Feet
31m
104 Feet
27m
89.5 Feet
2.9m
78.5 Feet
21m
69.5 Feet
5A 10A 15A 20A 25A 30A 35A 40A 45A
X
Fig.1
1.
2.
FILS
mm² AWG
FILS
mm² AWG
MAXIMUM AUTHORISED CURRENT IN THE WIRES
MAXIMUM AUTHORISED CURRENT IN THE WIRE
ABACUS FOR THE DIMENSIONING OF ELECTRIC WIRES
Dimensioning of electric wires
Safety and precautions
= Insufficient
It is essential and mandatory to dimension electrical wires correctly according to the currents used and the length of the
wires. Failure to dimension correctly may cause fire inside the vehicle. The product is equipped with static relay
outputs only. The use of static relays has several advantages, among which the suppression of external fuses.
The cable(s) connected to the + terminal(s) of the POLARIS must be protected by a fast blow fuse calculated on the
basis of the total current consumed according to the configuration (maximum 80A). Its section must be sufficient to
support this current.
To fix the wire size, you must follow three essential precautions:
R Know or determine the maximum current consumed at each static output.
R Setup each static output used to limit the maximum current from 0,5 to 20A thanks to the software provided by
IDEATEC S.A..
R Select the wire gauge according to its length and the current absorbed using the chart below :
IDEATEC S.A. assumes no liability and give the right to refuse any warranty if one
or more of the recommendations on page 2 and 3 are not being followed.
I All IDEATEC metal cases must be grounded correctly to the negative battery. Never defeat the ground conductor or
operate the equipment in the absence of a suitably installed ground conductor. Ideatec provides a kit
REF.P0035F0034 to make this connection. The connection must be made on one of the flanges of the Ideatec
system as shown in figure 1. The tooth washers must be positioned on either side of the terminal as shown in figure
1. The terminal provided allows a cable cross-section of 4 mm² to 6mm³, however Ideatec SA requires the
placement of a 6mm² cable with a maximum length of 50cm.