IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User Guide POLARIS V1.0 - Console V1.16 - Module V2.16
Page 31
7.
&Read the Unitherm-HD user guide for further information
7.15 EPM-103 Module
7.14 MFI Interface
Operating Voltage
Operating Current
Operating Temperature
Connexion Type
Weight
Dimensions (L x W x D)
Regl.10-05 Conformity
Interactive Backlighting
: from 10VDC to 30VDC
: 20mA
: from -25°C to +60°C
: RJ45 (non-crossed)
: 256 g.
: 105 x 92 x 45 mm
: E13-10R-05 14483
7.10 OpenLink Interface
7.9 Central Unit XLarge
Maximum Total Current
Operating Voltage
Operating Current (without charge)
Quiescent Current
Number of Positive Outputs
Maximum Current /pos. output
Number of Negative Outputs
Maximum Current / Negative Output
Number of Inputs
Operating Temperature
Weight
Dimensions (L x W x D)
: 80A + 80A
: de 10VDC à 30VDC
50mA
: 0mA
: 40 static and protected
: 15A & configurable
(outputs 1 to 17 and 21 to 37)
20A & configurable
(outputs 18 to 20 and 38 to 40)
: 28 static and protected
: 1A
: 28 positive or negative configurable
: from -25°C to +60°C
: 2060 g.
: 245 x 290 x 58 mm
Technical characteristics (continued)
7.12 VFI Interface
7.11 UNITHERM-HD Interface
7.13 ADI Interface
&Read the VFI user guide for further information
&Read the ADI user guide for further information
&Read the MFI user guide for further information
&Read the EPM-103 user guide for further information