User Guide POLARIS V1.0 - Console V1.16 - Module V2.16
Page 39
S3 - 1
S3 - 2
S3 - 3
S3 - 4
S3 - 5
S3 - 6
S3 - 7
S3 - 8
S3 - 15
S3 - 16
S5 - 1
S5 - 4
S5 - 2
S5 - 5
S5 - 3
S5 - 6
S3 - 9
S3 - 10
S3 - 11
S3 - 12
S3 - 13
S3 - 14
8.
FRONT VIEW
FOR SMALL - MEDIUM - LARGE - XLARGE
+ Ignition
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
Ground connected to <-> battery
Ground connected to <-> battery
Can 1 High Connection
Can 1 Low Connexion
Can 2 High Connection
Can 2 Low Connexion
FOR MEDIUM - LARGE - XLARGE
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
.....................................................................................................
8.8 Central Unit S, M, L & XL - Inputs
Positive input nr.1
Pos/Neg input nr.2
Pos/Neg input nr.3
Pos/Neg input nr.4
Pos/Neg input nr.5
Pos/Neg input nr.6
Pos/Neg input nr.7
Pos/Neg input nr.8
Analog input nr.1
Analog input nr.2
Ground
Ground
Can1-H
Can1-L
Can2-H
Can2-L
Pos/Neg input nr.9
Pos/Neg input nr.10
Pos/Neg input nr.11
Pos/Neg input nr.12
Pos/Neg input nr.13
Pos/Neg input nr.14
DESCRIPTION OF THE FUNCTION
POS.
DESCRIPTION
Connecting (continued)
The POLARIS Central Unit provides up to 28 isolated positive or negative inputs (configured by software, except
positive input 1 for + ignition), 2x analog inputs (battery monitoring for example) and 2x CAN connection (to connect to
the vehicle Canbus and equipment controlled by Canbus for example).