Idex HALE SmartCAFS - Adjusting Belt Tension

Idex HALE SmartCAFS
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 84 of 116
©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
ADJUSTING BELT TENSION
Figure 47: Belt Tension Adjustment Bolts
1. If the belt tension is less than required:
a. Loosen the center bolt located in the middle of the compressor mounting bracket. (See
Figure 47)
b. Tighten two jacking studs located at both ends of the mounting bracket.
2. If the belt tension is tighter than required:
a. Loosen the two studs located at both ends of the mounting bracket. (See Figure 47)
b. Tighten bolt located in the middle of the compressor mounting bracket. Also tighten the
two lock nuts against the bracket.
3. Verify that the belt tension is within the required limits. Readjust accordingly.