Domestic hot water maximum heating power kW (kcal/h) 28.1 (24,204)
Central heating maximum heat input kW (kcal/h) 24.9 (21,452)
DHW maximum useful heat output kW (kcal/h) 27.3 (23,478)
CH maximum useful heat output kW (kcal/h) 24.0 (20,640)
Minimum nominal heat input kW (kcal/h) 5.1 (4,382)
Minimum nominal heat output kW (kcal/h) 4.8 (4,128)
Eciency at 100% Pn (80/60°C) % 96.2
Eciency at 30% of the load (80/60°C) % 98.4
Eciency at 100% Pn (50/30°C) % 104.6
Eciency at 30% of the load (50/30°C) % 106.1
Eciency at 100% Pn (40/30°C) % 106.8
Eciency at 30% of the load (40/30°C) % 106.1
Central heating circuit
Adjustable central heating temperature (min. / max) °C 20 ÷ 80
System max. working temperature °C 90
System max. working pressure bar 3
System expansion vessel nominal/(real) capacity litres 10.0 / (8.3)
System expansion vessel factory-set pressure bar 1.0
Head available with 1000 l/h ow rate kPa (m c.a.) 26.91 (2.7)
DHW circuit
Hot water production useful heat output kW (kcal/h) 27.3 (23,478)
DHW adjustable temperature °C 10 ÷ 65
Domestic hot water circuit / DHW Circuit max. pressure bar 10
Domestic hot water circuit min. dynamic pressure bar 0.3 (Instant version)
D.H.W. min. withdrawal litres/min 1.5 (Instant version)
Flow rate in continuous service (∆T 30°C) litres/min 13.1 (Instant version)
Gas supply
Gas ow rate at METHANE burner (G20) MIN - MAX m
3
/h 0.54 ÷ 2.64 (2.98 D.H.W.)
Gas ow rate at LPG burner (G30) MIN - MAX kg/h 0.40 ÷ 1.97 (2.22 D.H.W.)
Gas ow rate at LPG burner (G31) MIN - MAX kg/h 0.40 ÷ 1.94 (2.19 D.H.W.)
Electric power supply V/Hz 230/50
Nominal power absorption A 1.2
Installed electric power W 160
Fan absorbed power W 24
Power absorbed by the indoor unit pump W 60
Power absorbed by the indoor unit in stand-by W 10
Electric insulation rating IP X4D
Appliance water content litres 2.8
Weight of empty generator kg 55.8
Eective eciency at 100% output >93+2·log Pn
(Italian Lgs. D. 192/05 as amended) (Pn = 24.0 kW)
23 MAGIS COMBO V2 HEAT GENERATOR TECHNICAL DATA