MAGIS COMBO 4 V2
39
- Correction factor stated DC = 0.9
- TOL = -25 °C
MAGIS COMBO 4 V2 Water ow temperature °C
55 60 65
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21)
-15 (-16)
-10 (-11) 3.81 2.08
-7 (-8) 4.05 2.10
-2 (-3) 3.66 1.75 3.47 1.92
2 (1) 3.36 1.53 3.18 1.70
7 (6) 3.90 1.32 3.76 1.38 3.62 1.44
10 (9) 4.15 1.37 3.94 1.41 3.74 1.46
15 (14) 4.77 1.38 4.53 1.43 4.29 1.47
20 (19) 5.39 1.40 5.12 1.44 4.85 1.48
MAGIS COMBO 4 V2 Water ow temperature °C
40 45 50
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21) 3.34 1.56 3.21 1.72
-15 (-16) 3.85 1.64 3.74 1.74 3.62 1.82
-10 (-11) 4.37 1.70 4.24 1.81 4.11 1.90
-7 (-8) 4.50 1.75 4.40 1.95 4.23 2.03
-2 (-3) 4.23 1.46 4.07 1.59 3.87 1.67
2 (1) 3.97 1.16 3.73 1.23 3.55 1.38
7 (6) 4.30 0.97 4.20 1.09 4.05 1.21
10 (9) 4.71 0.97 4.61 1.10 4.38 1.23
15 (14) 5.39 0.97 5.30 1.11 5.03 1.25
20 (19) 6.07 0.99 5.98 1.12 5.68 1.26
26 “POWER” AND “ABSORPTION” IN CENTRAL HEATING MODE
MAGIS COMBO 4 V2 MAGIS COMBO 4 PLUS V2
MAGIS COMBO 4 V2 Water ow temperature °C
25 30 35
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21) 3.76 1.21 3.65 1.30 3.48 1.46
-15 (-16) 4.28 1.28 4.16 1.37 3.96 1.54
-10 (-11) 4.87 1.32 4.73 1.41 4.51 1.59
-7 (-8) 4.97 1.29 4.83 1.38 4.60 1.55
-2 (-3) 4.75 1.10 4.62 1.18 4.40 1.33
2 (1) 4.54 0.91 4.41 0.98 4.20 1.10
7 (6) 4.75 0.70 4.62 0.75 4.40 0.85
10 (9) 5.19 0.71 5.05 0.76 4.81 0.85
15 (14) 5.92 0.72 5.76 0.77 5.48 0.87
20 (19) 6.65 0.73 6.47 0.78 6.16 0.88