MAGIS COMBO 6 V2
42
- Correction factor stated DC = 0.9
- TOL = -25 °C
MAGIS COMBO 6 V2 Water ow temperature °C
55 60 65
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21)
-15 (-16)
-10 (-11) 4.52 2.80
-7 (-8) 4.84 2.84
-2 (-3) 4.45 2.60 4.22 2.89
2 (1) 4.16 2.06 3.94 2.29
7 (6) 4.80 1.81 4.53 1.88 4.27 1.95
10 (9) 5.43 1.92 5.16 1.98 4.89 2.04
15 (14) 6.39 1.97 6.07 2.03 5.75 2.09
20 (19) 7.34 2.01 6.98 2.08 6.61 2.14
MAGIS COMBO 6 V2 Water ow temperature °C
40 45 50
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21) 4.18 2.10 4.01 2.32
-15 (-16) 4.81 2.21 4.67 2.34 4.53 2.46
-10 (-11) 5.18 2.29 5.02 2.43 4.87 2.55
-7 (-8) 5.38 2.26 5.27 2.51 5.05 2.68
-2 (-3) 5.15 1.91 4.94 2.08 4.70 2.34
2 (1) 4.91 1.57 4.62 1.65 4.39 1.86
7 (6) 5.70 1.37 5.40 1.51 5.10 1.66
10 (9) 6.30 1.38 6.04 1.53 5.74 1.73
15 (14) 7.29 1.39 7.10 1.57 6.74 1.77
20 (19) 8.28 1.42 8.16 1.61 7.75 1.81
28 “POWER” AND “ABSORPTION” IN CENTRAL HEATING MODE
MAGIS COMBO 6 V2 MAGIS COMBO 6 PLUS V2
MAGIS COMBO 6 V2 Water ow temperature °C
25 30 35
Air temperature °C
d.b. (w.b.)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
-20 (-21) 4.69 1.63 4.56 1.75 4.35 1.97
-15 (-16) 5.35 1.73 5.20 1.85 4.95 2.08
-10 (-11) 5.77 1.78 5.61 1.91 5.34 2.15
-7 (-8) 5.94 1.66 5.78 1.78 5.50 2.00
-2 (-3) 5.78 1.44 5.62 1.55 5.35 1.74
2 (1) 5.62 1.23 5.46 1.32 5.20 1.48
7 (6) 6.48 1.01 6.30 1.09 6.00 1.22
10 (9) 7.08 1.02 6.88 1.10 6.55 1.23
15 (14) 8.08 1.04 7.85 1.11 7.48 1.25
20 (19) 9.07 1.05 8.82 1.13 8.40 1.27