MAGIS COMBO 4 V2 Water ow temperature °C
15 18 25
Air temperature °C
d.b.
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
10 5.15 0.82 5.54 0.81 6.09 0.83
20 4.95 0.93 5.33 0.92 5.86 0.94
30 4.75 1.03 5.11 1.03 5.62 1.05
35 4.65 1.10 5.00 1.09 5.50 1.11
46 4.43 1.21 4.77 1.20 5.24 1.23
MAGIS COMBO 4 V2 Water ow temperature °C
7 10 13
Air temperature °C
d.b.
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
Max. output
(kW)
Max. absorbed
(kW)
10 3.99 0.83 4.37 0.82 4.76 0.82
20 3.83 0.94 4.21 0.93 4.58 0.93
30 3.68 1.05 4.04 1.04 4.39 1.04
35 3.60 1.11 3.95 1.11 4.30 1.10
46 3.43 1.23 3.76 1.22 4.10 1.22