22
INSTALLERUSERMAINTENANCE TECHNICIANTECHNICAL DATA
“Comando Amico Remoto” (Remote Control Device)
V2
or On/O chrono-thermostat electrical connection (Optional).
e operations described below must be performed aer having removed the voltage from the
appliance.
Any On/O room thermostat or chrono-thermostat must be connected to terminals 44/40 and 41, eliminating jumper X40.
Make sure that the On/O thermostat contact is of the “clean” type, i.e. independent of the mains voltage, otherwise the P.C.B. would be
damaged.
Any Comando Amico Remoto (remote control) V2 must be connected to terminals 44/40 and 41, eliminating jumper X40 on the P.C.B.
(Fig. 40).
e boiler can only be connected to one remote control.
If the Comando Amico Remoto remote control
V2
or any other On/O chrono-thermostat is used arrange two separate lines in
compliance with current regulations regarding electrical systems.
Ensure elimination of this risk before making the appliance electrical connections.