87
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
4.5 TECHNICAL PARAMETERS FOR COMBINATION BOILERS IN COMPLIANCE WITH
REGULATION 813/2013
Model/s: VICTRIX OMNIA
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
20 kW Seasonal energy eciency of central heating η
S
91 %
For central heating only and combination boilers: useful heat output For central heating only and combination boilers: useful eciency
At nominal heat output in high temperature
mode (*)
P
4
20,2 kW
At nominal heat output in high temperature
mode (*)
η
4
87,3 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
6,6 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
95,8 %
Auxiliary electricity consumption Other items
At full load el
max
0,018 kW Heat loss in standby P
stby
0,055 kW
At partial load el
min
0,011 kW Ignition burner energy consumption P
ign
0,000 kW
In standby mode P
SB
0,004 kW Emissions of nitrogen oxides NO
x
32
mg/
kWh
For mixed central heating appliances
Stated load prole XL Domestic hot water production eciency η
WH
82 %
Daily electrical power consumption Q
elec
0,138 kWh Daily gas consumption Q
fuel
23,932 kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return
temperature.
e eciencies and NO
x
values in the following tables refer to the gross caloric value.