3.11 QUICK CALIBRATION
is function allows you to calibrate the boiler automatically without requiring or giving the possibility to alter the parameters. Typical-
ly “fast calibration” is used aer having set the type of ue in menu “F”, which once altered causes anomaly “72”.
Before carrying out the fast calibration, ensure that all the requirements indicated in the relevant paragraphs have been met
(Par. 1.25 - 1.26).
No active requests for central heating or D.H.W. production must be present and the boiler must not be in “Stand-by” mode.
In the event of anomaly “72” (Par. 2.5) the boiler cancels any requests by itself.
e energy produced is dissipated via the heating circuit; alternatively, the energy can be released from the DHW circuit by opening any
hot water tap.
In this case the only active temperature control is the ow probe that limits the maximum temperature exiting the boiler at
90°C, therefore be careful not to get burned.
49
Press and hold buttons “
” and “ ” for more than 5 seconds.
50
e display will show two dashes “--” ashing. Now enter the password “72” to
activate fast calibration.
51
Press the “
” key to activate calibration.
Once the function is active, the appliance sequentially carries out the proce-
dures required to calibrate the appliance with the nominal, intermediate and
minimum heat output values.