83
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
4
TECHNICAL DATA
4.1 VARIABLE HEAT OUTPUT
e power data in the table has been obtained with intake-exhaust pipe measuring 0.5 m in length. Gas ow rates refer to net
caloric value below a temperature of 15°C and at a pressure of 1013 mbar.
METHANE
(G20)
PROPANE
(G31)
HEAT
OUTPUT
HEAT
OUTPUT
MODULATION
GAS FLOW RATE
BURNER
MODULATION
GAS FLOW RATE
BURNER
(kW) (kcal/h) (%) (m³/h) (%) (kg/h)
25,0 21500
D.H.W.
99 2,72 99 2,00
24,0 20640 95 2,61 95 1,92
23,0 19780 91 2,50 91 1,84
22,0 18920 87 2,40 87 1,76
20,2 17372
HEAT. +
D.H.W.
79 2,20 79 1,62
20,0 17200 78 2,18 78 1,60
19,0 16340 74 2,07 74 1,52
18,0 15480 69 1,96 69 1,44
17,0 14620 65 1,86 65 1,36
16,0 13760 60 1,75 60 1,28
15,0 12900 56 1,64 56 1,20
14,0 12040 51 1,53 51 1,13
13,0 11180 46 1,43 46 1,05
12,0 10320 42 1,32 42 0,97
11,0 9460 37 1,21 37 0,89
10,0 8600 32 1,10 32 0,81
9,0 7740 27 0,99 27 0,73
8,0 6880 22 0,88 22 0,65
7,0 6020 17 0,78 17 0,57
6,0 5160 11 0,67 11 0,49
5,0 4300 6 0,56 6 0,41
4,0 3440 1 0,45 1 0,33