IB-11B012 INDUSTRIAL INDEXING SYSTEMS, INC.
USER'S GUIDE MOTION CONTROL SYSTEM, MSC-250
3 - 4 OPERATION AUGUST 1998
3. Make sure the MODE selector switch is set to the desired power-up configuration
(refer to Figure 3.1).
Normal operation = Port 1, 2, & 3, default to 9600 Baud - Packet Protocol.
Position 0 = Normal Operation.
The Ports not mentioned in the following setting definitions stay at their "Normal
Operation" defaults.
Position A = Normal Operation
Position B = Port 3 = 19200 Baud - Packet Protocol.
Position C = Port 3 = 38400 Baud - Packet Protocol.
Position D = Port 1 = 19200 Baud - Packet Protocol.
Position E = Port 1 = 38400 Baud - Packet Protocol.
Position F = Reserved
These above port settings are only power up defaults, and can be changed by the
users' Macroprogram at any time.
4. Close and latch the controller cover.
5. If necessary for data collection or if the program is to be burned in to a PROM, open
the PROM POCKET by moving the handle to a position perpendicular to the pocket.
Load a PROM into the PROM POCKET and close the latch on the pocket by
moving the pocket handle to a position parallel to the pocket.
6. Turn on power to the controller.
7. Follow the instructions in the Macroprogram Development System Instruction Book
to load the program to non-volatile memory.