IB-11B012 INDUSTRIAL INDEXING SYSTEMS, INC.
USER'S GUIDE MOTION CONTROL SYSTEM, MSC-250
1 - 24 DESCRIPTION MARCH 2003
DIGITAL FILTERING (Slew Control):
Unit Bits per 10 Milliseconds
Range (programmable) 1 to 2048 bits
Resolution 1 part in 2048 bits
1.4.5 INPUT/OUTPUT MODULES
I/O INTERFACE: 16 positions, on-board, discrete
32 positions, on expansion modules
(16 Programmable Limit Switches max.)
DC INPUT MODULE (HSI-250)
(High Speed Input)
JUMPER INSTALLED
Input Voltage Range 4.5 to 8 VDC
Input Current at Max. Line 28 ma
Input allowed for No Output
JUMPER CUT
Input Voltage Range 9 to 24 VDC
Input Current at Max. Line 38 ma
Input allowed for No Output
Isolation Input-to-output 2500 V
rms
Turn-on Time 6 ms
Turn-off Time 6 ms
DC INPUT MODULE (IDC15)
Input Voltage Range 10 to 32 VDC
Input Current at Max. Line 25 ma
Input allowed for No Output 1 ma (3 V)
Isolation Input-to-output 4000 V
rms
Turn-on Time 5 ms max.
Turn-off Time 5 ms max.
DC Input Module - High Speed (HSI-250)
Input Voltage 5vdc or 15vdc Jumper Selectable
Input Current at Max. Line 25 ma
Input Allowed For No Output 2 V
Isolation Input-to-output 2500 VAC
Turn-on Time 100u Sec max.
Turn-off Time 100u Sec max.