EasyManuals Logo

Industrial Indexing Systems MSC-250 User Manual

Default Icon
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
INDUSTRIAL INDEXING SYSTEMS, INC. IB-11B012
MOTION CONTROL SYSTEM, MSC-250 USER'S GUIDE
AUGUST 1998 MAINTENANCE 4 - 11
f. Move the encoder shaft to find two different voltages. The greater voltage
should be no less than +2.5 VDC. The lesser voltage should be no more
than -2.5 VDC. If the readings are out of specification, replace the encoder.
6. Check the encoder connection cable for shorts or breaks in the cable.