Introduction to Digital Power Conversion
XMC4000/1000 Family
PWM Generation
Application Guide 30 V1.0, 2015-01
Monitoring the FOT pulse rate
The FOT pulse rate is monitored by the free running f
maxmin
timer (Slice2). This timer is flushed on
each FOT timer start.
If the next ZCD event occurs before the f
max
-period compare event, then the next FOT start must wait
because of f
max
-period. If no ZCD occurs, then the FOT-start has to wait for the timeout.
The FOT timer will start on the falling edge of the f
maxmin
timer status.
There can be any of three different event flow scenarios behind a FOT pulse start, depending on
whether the ZCD-event occurs after or before the ZCD, or if there is no ZCD at all, in relation to the
f
max
-period compare event (here named CMP-event).
All event flow scenarios will terminate by an end-of-FOT event, alias EOF-event.
Notes:
1. For readability, all redundant actions in the event flows described here have been removed.
2. All event flow scenarios will begin and end with the status bit of all timers = 0; i.e. ST0=0, ST1=0, ST2=0,
ST3=0.
3.
= “consequently the successive event will follow”.
4. // = “a parallel (synchronous) event flow, connected to the root event”.
5. STn=STm means “Status-bit Override; i.e. status bit STn is copied with status bit STm”.
6. # = “inverted value of”.
CRM Mode: Event Flow ‘after
i.e. ZCD-event > CMP-event
1. CMP-event: ST2=1
2. ZCD-event: ST1=ST2 ( FOT) flush-Slice2 ST2=0 start-Slice1
3. EOF-event: ST1=0
DCM Mode: Event Flow ‘before
i.e. ZCD-event < CMP-event
1. ZCD-event: Start-Slice0 // Start-Slice3 ST3=1 (delayed 1 clk by compare)
2. CMP-event: ST2=1 capture-Slice0 ST0=1 ST2=#ST3 start-Slice1 ST1=1 (
FOT) (flush-Slice2 + stop&flush-Slice0)
3. EOF-event: ST1=0 stop&flush-Slice3 ST3=0
Event Flow “No ZCD”
No ZCD at all until due f
min
-period = Timeout at Slice2 Period-Match
1. CMP-event: ST2=1
2. Timeout: ST2=0 Start-Slice1 ST1=1 ( FOT) flush-Slice2
3. EOF-event: ST1=0
The Auxiliary Timer (Slice0). Monitoring the DCM Window
This timer is essential for the status bit-override ST2=#ST3operation specifically, since there is no
direct “ST2=1 ST2=#ST3” event interconnectivity path; i.e. a slice cannot event request itself.
Optionally, Slice0 will work as a DCM window monitor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infineon XMC Series and is the answer not in the manual?

Infineon XMC Series Specifications

General IconGeneral
BrandInfineon
ModelXMC Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals