Introduction to Digital Power Conversion
XMC4000/1000 Family
Modulation
Application Guide 59 V1.0, 2015-01
6.2.4 ACC Center Aligned Scheme
In this diagram the CCU4/8 slice timer works in center aligned mode.
The average current is sensed via the VADC connection to the current sensor each time the timer hits
period-match, which occurs at the "

I
L
point where I
OUT
(Avrg) is due.
The CPU load is low in this mode, but at the cost of resolution.
Figure 44 Average Current Control (ACC) Timing Scheme Center Aligned Mode
Accuracy Considerations
Center aligned mode “costs” an accuracy reduction of factor two.
If for example the compare level is changed by one, then the duty-cycle is changed in steps of two
(due to the impact from both rising and falling sides).
This disadvantage can be overcome by incorporating the High Resolution PWM unit (HRPWM).