Introduction to Digital Power Conversion 
  XMC4000/1000 Family 
 
  Application Software 
Application Guide  89  V1.0, 2015-01 
     
8.3  Safety 
Protections  ->  Over-Voltage  (OV)  /  Over  Current  OC)  protections,  reaction  to  OV/OC:  e.g.  TRAP 
request with shut-down support by hardware and software service providers. 
Feed-Forward  Control  option,  by  including  monitoring  of  input  variations  for  early  prediction  of 
protection reaction. 
8.4  Communication capabilities 
The XMC serial communication modules support medium access and data transmission to various 
extents  by  protocol  providers  in  hardware,  depending  on  category,  prepared  for  embedded  DMA-
support (optionally) and FIFO buffers for software drivers with the following communication protocols: 
  ETH 
Ethernet - 10/100 MBit/s data transfer rates in compliance with the IEEE 802.3-2002 standard / 
Prepared for Internet connected applications using IPv4 and IPv6 / Supports implementation of 
IEEE1588 time synchronisation for Real Time Ethernet protocols. 
  CAN 
MultiCAN, Multi Controller Area Network module - Independently operating CAN nodes with Full-
CAN V2.0 B-active and using standard frames with 11-bit identifiers as well as extended frames 
with 29-bit identifiers / Exchangable data and remote frames via a gateway functions, optionally 
supported by message FIFO buffers.  
  USB 
Universal Serial Bus - Fully compliant with the USB 2.0 specification, flexible as a host-only or 
device-only controller, satisfying Dual-Role Device (DRD) controller, supporting both device and 
host functions / Compliant with the On-The-Go Supplement to the USB 2.0 specification, revision 
1.3.  
  Serial 
USIC,  Universal  Serial  Interface  Channel  module  -  covering  several  serial  communication 
protocols such as I2C, SPI, UART. 
  PMBus 
Power Management Bus, targeted for digital management of power supplies, is a protocol based 
on  I2C  communication.  This  can  be  implemented  using  USIC  module  in  XMC.  Customized 
commands can be implemented as well.   
8.5  Data logging / Firmware updates 
These Apps enable data logging or maintenance of embedded software remotely by firmware updates 
via the alternative communication units: ETH, CAN, USB, Serial, PMBUS, or other serial protocols. 
8.6  Human Machine Interface 
XMC supports Human Machine Interface (HMI) with the embedded LED and Touch-Sense (LEDTS) 
units (for LEDs and touch pads), that offers interface to the power supply. Display drives can also be 
controlled with XMC (Communication/GPIO interfaces).