Chapter 3 Inputs-Outputs
XtrapulsPac Installation Guide
3.3.2 - XtrapulsPac-ed version
3.3.2.1 - X1 connector for Hiperface DSL® encoder (Sub D 15 pin female)
The Hiperface DSL® configuration is software selectable and saved in the drive EEPROM.
PIN
FUNCTION
I/O
DESCRIPTION
11
+U / DSL+
I/O
Two-core cable Hiperface DSL® signals:
Power supply output specifications: 9.5 V +/- 0.5 V -
max.150 mA.
4
GND / DSL-
I/O
12
TC (thermal sensor)
I
Motor thermal sensor inputs.
The valid measurement range is between 100 Ω and 44
kΩ.
13
TC (thermal sensor)
I
Others
Reserved
SPECIFICATION OF THE HIPERFACE DSL® INTERFACE
100µH
470nF
470nF
56
56
+9.5V
Transceiver
65LBC176
+5V
DSL+
DSL-
2.2µF
100µH