72
XtrapulsPac Installation Guide
Chapter 5 - Appendix
Vibrations which exceed these limits or the use on mobile equipment are considered as unusual operating
conditions.
C
-
UNUSUAL OPERATING ENVIRONMENT CONDITIONS
The use of the power converter, of its pertaining control system and of the servo in conditions which are
diverging from the usual ones defined by the IEC 60146-1-1 standard must be considered as abnormal.
These abnormal operating conditions must be specified by the purchaser.
Abnormal operating conditions as those listed below may require a special construction or special
protections. The conditions below must be notified if they are known or specified:
1. Exposure to corrosive gas.
2. Exposure to excessive moisture (relative moisture exceeding 85 %).
3. Exposure to excessive dust.
4. Exposure to abrasive dust.
5. Exposure to water steam or condensation.
6. Exposure to oil steam.
7. Exposure to explosive dust or gas mixtures.
8. Exposure to salt air.
9. Exposure to abnormal vibrations, shocks, jerking.
10. Exposure to inclemency or water dripping.
11. Exposure to unusual storing or freight conditions.
12. Exposure to sudden or rough temperature variations.
13. Abnormal exiguity of the available room.
14. Abnormal high nuclear radiations.
15. Altitude higher than 1000 m.
16. Long storage periods.
17. Outdoor equipment.
D
-
INSTALLATION, COMMISSIONING AND OPERATION
Normal and abnormal operating conditions apply the same way to installation, commissioning and use.
E
-
EQUIPMENT STORAGE
At receipt, the equipment must be immediately stored under adequate shelter. The transport packaging is
not suited to outdoor or non-protected storing.
Climatic conditions
Equipments must be stored in the environment conditions specified by the IEC 60721-3-1 standard. This
includes:
1 -
Room temperature: class 1K4
-25°C to +55°C
2 -
Relative moisture: class 1K3
5 % to 95 %
Modules and panels must be protected against condensation. Rough temperature and moisture variations
should be avoided, as far as possible. If the temperature of the storing room is varying such as to subject
the equipment to condensation or to frost, the equipment must then be protected by a reliable heating
system which will keep it at a temperature slightly higher than the surrounding air temperature.
If the equipment has been subjected to a low temperature during a long time, it should not be unpacked
before having reached the surrounding air temperature, in order to avoid condensation. Such moisture in
some parts of the equipment may involve a faulty electric insulation.

Table of Contents

Other manuals for Infranor XtrapulsGem

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infranor XtrapulsGem and is the answer not in the manual?

Infranor XtrapulsGem Specifications

General IconGeneral
BrandInfranor
ModelXtrapulsGem
CategoryController
LanguageEnglish

Related product manuals