24 Using the Prime system
Anti-intrusion control panels
Keyfobs (paragraph 7-3-3 Outputs management)
Telephone (paragraph 8-3-3 Activation of outputs)
Web browser (paragraph 9-3-3 Viewing and activations)
AlienMobile Application
InimCloud
5-7
Change code PIN
This section allows you to change the User Code PIN you used for access and also the PINs of
other users with a lower rank in the system hierarchy (refer to paragraph 3-1 User Codes).
In order to be EN50131 compliant, all PINs must have 6 figures.
This operation can be done through:
•LCD Keypad (paragraph 6-6-9 Change code PIN)
Alien keypad (paragraph 6-7-10 Change code PIN
5-8
Change telephone numbers
Users can edit the contact numbers used by the dialer of the Prime control panel.
Only contact numbers with at least one partition in common with the entered PIN and keypad
in use will be shown.
This operation can be done through:
•LCD Keypad (paragraph 6-6-10 Edit telephone numbers)
Alien keypad (paragraph 6-7-11 Edit telephone numbers
5-9
Overtime request
This operation can be carried out under the following conditions only.
The partition concerned must be timer-controlled.
The partition auto-arm option must be enabled (refer paragraph 5-5 Activations).
Each overtime request postpones the auto-arming operation by 30 minutes.
This operation can be done through:
•LCD Keypad (paragraph 6-6-11 Overtime request)
Alien keypad (paragraph 6-7-12 Overtime request
Proximity readers (paragraph 7-3-4 Overtime request)
Keyfobs (paragraph 7-3-4 Overtime request)
Telephone (paragraph 8-3-4 Overtime request)
5-10
Thermostat
The "thermostat" function of Prime control panels makes it possible to manage boilers or air
conditioners via keypads equipped with thermometers.
There are two operating modes:
Summer/Air-Conditioning
When the sensor detects that the temperature has risen above the value set by the user,
the output connected to the air-conditioning system will activate (indicated on the display
by ).
Winter/Heating
When the sensor detects that the temperature has fallen below the value set by the user,
the output connected to the heating system will activate (indicated on the display by
).
This function provides 5 operating modes for the user to choose from:
Off - the thermostat is off; the output associated with the heating or air-conditioning
system is deactivated.