34 Keypads
Anti-intrusion control panels
6-6-2
Arming commands and scenarios
If you request an arm-partition command at a keypad (for one or more partitions) and not all
the zones involved are in standby status (thus execution of the command would generate an
instant alarm), the keypad will provide a list of the zones concerned.
You can scroll the list and check the zones which are not in standby status (open zones). If
you wish to implement the command, the visualized zones will generate an instant alarm.
If you request an arm-partition command at a keypad (for one or more partitions) and
conditions (programmed by the installer) which lower the security of the system are present,
the keypad will provide a list of the conditions concerned, as shown in the figure opposite.
The user can scroll through the list to see the causes of reduced security, then decide whether
or not to force the arming command.
The user can operate via the keypad in two ways:
• activate the shortcuts associated with keys , ..., , shown on the display (with or
without code entry) of the “Arm/Disarm” type (shortcut no. 1) that will apply the
programmed scenario.
If the shortcut is activated by the entry of a code PIN with the “Fixed Length” attribute, and
if all the partitions the user controls are disarmed, they will switch status and arm;
likewise, if all the partitions the user controls are armed they will switch status and disarm.
• Access the “Arm/Disarm” section in the user menu. In this section it is possible to select
the arm or disarm mode for each partition individually:
1. Select the desired partition, using keys and .
2. Select the required operating mode for the selected partition, using keys and
.
• “D”, to disarm.
• “A”, to arm in Away mode (entire system armed)
• “S”, to arm in Stay mode (system partially armed).
• “I”, to arm in Instant mode (no delays)
• “N”, not to change the operating status.
3. Once you have set the arming modes on all the partitions, press OK.
ENTRY TIME
WINDOW
If during the entry time a code is entered, and if the code is authorized to access the “Arm/
Disarm” section of the user menu, the partitions common to the code and keypad will disarm
immediately.
SHOW SCENARIO
If the control panel “Show scenario” (or “View scenario” on keypad) option is active, the left
side of the second line on the screen will display the current scenario.
6-6-3
Voice memo and intercom functions
The voice functions available at the keypad are:
• Record message in the voice memo box
• Playback message in the voice memo box
• Delete message in the voice memo box
• Voice communication with another keypad.
The user can operate via the keypad in two ways:
• activate the shortcuts associated with keys , ..., (shown on the display) with or
without code entry.
Zone not ready
Panel T01
Panel T02
Panel T03
Faults ongoing
Low battery
Tel. line down
User Code
Manage alarms
Arm/Disarm op.
Voice functions
Arm/Disarm op.
PARTITION 001
Away
ADS-------
Table 6-10: Shortcut for Arm/Disarm partition operations from a keypad
Shortcut User menu section Operation
Arm/Disarm n.1
/
Activate the scenario selected from
those available.
Arm/Disarm
menu
n.12
Arm/Disarm op.
Accesses the section containing the list
of partitions which the user can access
and change the operating status.