(1) The unit of target speed shall be determined according to F8-64: 0 (Hz) 1 (RPM)
(2) When the unit is Hz, the correlation (F0-22) needs to be set according to the unit of frequency. If F0-22 =
2, the frequency resolution is 0.01Hz. Assuming that the target frequency needs to be set to 10.00hz,
the communication needs to write 1000; If F0-22 = 1, the frequency resolution is 0.1Hz. Assuming
that the target frequency needs to be set to 10.0hz, the communication needs to write 100.
(3) When the unit is rpm, the maximum speed only supports - 32768rpm ~ 32767rpm. If it exceeds this
range, please use Hz bit unit to support higher speed setting.
(1) Speed setting, speed setting through ramp generator.
(2) The speed display unit is consistent with the description of 6042h.
(1) The actual operating speed of inverter, if VF control, represents the synchronization frequency; In the
case of SVC control, the speed is estimated according to the motor mathematical model.
(2) The speed display unit is consistent with the description of 6042h.