28
INOVANCE TECHNOLOGY EUROPE GmbH
MD800 EtherCAT Starting Guide_EN_v1.1_20211109.docx
6046h
vl velocity min max
amount
Accessibility
RW
Can
It
map
RPDO
Correlation
mode
vl
Data
range
OD
data
range
factory
setting
Od
default
(1) The minimum or maximum speed at which the inverter operates.
Subindex
0h
name
Number of
minimum /
maximum speed
sub indexes
Setting
effective
-
data
structure
-
data
type
Uint8
Accessibility
RO
Can It
map
NO
Correlation
mode
vl
Data
range
-
factory
setting
2
Subindex
1h
name
Minimum speed
vl velocity min
amount
Setting
effective
-
data
structure
VAR
data
type
Uint32
Accessibility
RW
Can
It
map
RPDO
Correlation
mode
vl
Data
range
0~65535
factory
setting
0
(1) The minimum allowable speed of the inverter, in RPM. The actual set value can be seen by querying f0-
14, and the unit of f0-14 is Hz
Subindex
2h
name
Maximum speed
vl velocity max
amount
Setting
effective
data
structure
VAR
data
type
Uint32
Accessibility
RW
Can
It
map
RPDO
Correlation
mode
vl
Data
range
0~65535
factory
setting
1500
(1) The maximum allowable speed of the inverter, in RPM, is limited by the maximum frequency (F0-10).