63
INOVANCE TECHNOLOGY EUROPE GmbH
MD800 EtherCAT Starting Guide_EN_v1.1_20211109.docx
202: Expansion card 2 AI2
F4-31
AI curve 1
minimum input
-10.00V~10.00V
When the main frequency is set
through the analog input, the AI
terminal is used as the frequency
source setting, and 5 different AI
curves can be selected for each AI
terminal.
AI curve is the relationship between
the analog input voltage (or analog
input current) and the percentage
relative to the maximum frequency
(F0-10). AI song
The x-axis of the line represents the
analog input voltage (or analog input
current), and the y-axis represents the
set value corresponding to the analog
input, that is, the relative maximum
frequency
(F0-10) percentage.
There are 5 types of AI curves, among
which curve 1, curve 2, and curve 3
are all 2-point curves, and the
relevant parameters are F4-31~F4-42;
curve 4 and curve 5 are both
It is a 4-point curve, and the relevant
parameters are A6-00 ~ A6-15.
There are 2 points on AI curve 1~3,
namely the minimum input point and
the maximum input point. F4-31
corresponds to the x-axis of the
minimum input point of AI curve 1,
that is, the minimum modulus
Analog input voltage (or minimum
analog input current).
F4-32
AI curve 1
minimum input
corresponding
setting
-100.0%~100.0%
The y-axis corresponding to the
minimum input point of AI curve 1,
that is, the set value corresponding to
the minimum analog input.
F4-33
AI curve 1
maximum input
-10.00V~10.00V
The x axis corresponding to the
maximum input point of AI curve 1,
that is, the maximum analog input
voltage (or the maximum analog input
current).
F4-34
AI curve 1
maximum input
corresponding
setting
-100.0%~100.0%
The y-axis corresponding to the
maximum input point of AI curve 1,
that is, the set value corresponding to
the maximum analog input.
F4-35
AI curve 2
minimum input
-10.00V~10.00V
The x axis corresponding to the
minimum input point of AI curve 2 is
the minimum analog input voltage (or
minimum analog input current).
F4-36
AI curve 2
minimum input
-100.0%~100.0%
The y-axis corresponding to the
minimum input point of AI curve 2 is

Related product manuals